GenerLink™ allows customers to safely connect a portable generator to their home.
- The GenerLink is a UL listed transfer switch.
- Meter-base unit with 40 amp generator lug
- Comes with a 20 foot cord
- 200 amp meter-base surge protection
- Can be installed in less than 20 minutes
Contact your local Clay County Electric Cooperative Corporation office for more details
*By accessing the GenerLink website you are leaving the Clay County Electric website and entering a website maintained by a third party. The third party is entirely responsible for the content of their website.
- Download the GenerLink FAQ (PDF)
- To download and access PDF files on your computer, download Adobe Acrobat Reader.
GenerLink FAQ
Yes. GenerLink™ is an interconnection device that enables you to connect your portable generator directly to your home’s wiring system. During a power outage, your generator becomes your source of emergency back-up power. GenerLink is designed as an alternative to expensive transfer switches and hazardous extension cords.
GenerLink™ offers several advantages over traditional transfer switches:
- GenerLink is installed outside your home at the electric meter providing easy access to your generator. Installation of a transfer switch may require re-wiring your home’s electric system.
- With GenerLink, you have the flexibility of selecting the appliances you want to run from your home’s breaker panel, up to the capacity of your generator. Most basic transfer switches have 6 to 8 hard-wired circuits. This limits the number of circuits you can connect to the transfer switch.
- Since GenerLink uses your existing breaker panel, you can run any large 120 or 240-volt appliance up to your generator’s capacity. Your well pump, water heater, sump pump, electric range, and clothes dryer are just some of the appliances that can be run on a rotation basis with GenerLink. Many transfer switches and sub panels have only 1 or 2 240-volt circuits rated at 15 or 20-amps. Heavier loads, such as water heaters and electric ranges, may not be accommodated by these transfer switches and sub panels.
Your generator continues to power your home until you turn it off. Once you turn off your generator, GenerLink™ will automatically switch your home back to utility power. GenerLink has a built-in safety feature that prevents back feeding the generator’s power into the utility lines, eliminating hazardous conditions for you and for utility service personnel.
There is no regular maintenance required for GenerLink™. However, it is recommended that you test your generator every 15 to 30 days.
There are 3 indicator lights on GenerLink™, 1 green, 1 yellow, and 1 red.
- When the green light is illuminated, this represents a normal condition where utility power is present. When your utility has restored power you can de-energize and disconnect your generator from GenerLink.
- When the yellow light is illuminated, this indicates that the household load is greater than 30 amps. It is normal for the yellow status light to be illuminated while utility power is present. The load must be reduced by turning off circuit breakers before the GenerLink unit can be operated with a generator.
- If the red light is illuminated at any time or in conjunction with the green light, there is a potential problem and you should have the unit serviced immediately. (Refer to the Terms and Conditions for service instructions)
Your generator should have a circuit breaker that will activate in the event of an overload. If it does not have this feature, it is not suitable for use with GenerLink™. If the generator’s circuit breaker trips, turn off all the household circuit breakers in your breaker panel, reset the circuit breaker on the generator, and restart the generator. Please refer to your generator owner’s manual for complete instructions on the safe operation of your generator.
Remember, generator exhaust gases contain deadly carbon monoxide. The generator should never be operated inside; this includes basements, crawl spaces, and/or attached garages. Please consult your generator owner’s manual for complete instructions on the safe location for and operation of your generator.
To remove, replace, or repair your GenerLink™, you must contact Clay County Electric Cooperative Corporation (CCECC). Only CCECC technicians have access to GenerLink. Do not, under any conditions, attempt to remove and/or repair GenerLink yourself.
The appliances in the average home consume relatively low amounts of electricity to operate once they are started. However, many of them require a significant amount of electricity to start up the appliances. Please review the appliance guide to determine the start-up wattage required for individual appliances.
GenerLink™ is completely sealed inside the meter socket and does not represent a hazard. However, generators should not be operated during rain or snow unless they are protected from the elements. Please consult your generator manufacturer, distributor and/or owner’s manual for instructions on the safe operation of your generator.
A power cord consists of a standard GenerLok™ connector that will attach to GenerLink™, a four-wire, 10 gauge, heavy duty, outdoor rated, water-resistant wire and an appropriate NEMA connector for your generator. Your generator may have a 20-amp or 30-amp, 120/240-volt output that will require a 20-amp or 30-amp NEMA connector. The length of the power cord should be as close to the actual measured distance from the meter to the generator as possible in order to maintain your generator’s power quality.
GenerLok™ is a unique fitted connector, exclusively available for GenerLink™. GenerLok allows you to plug your generator directly into GenerLink without needing a separate interconnection box. GenerLok easily connects to GenerLink and locks the power cord safely in place when GenerLink is being used.